    Effect of temperature on the performance of brain PET using GAPD

  • Author

    Huh, Y. ; Choi, Y. ; Jung, J.H. ; Hu, W. ; Kang, L.H. ; Kim, S.S. ; Jung, J. ; Kim, B.T.

  • Author_Institution
    Dept. of Electron. Eng., Sogang Univ., Seoul, South Korea
  • fYear
    2011
  • fDate
    23-29 Oct. 2011
  • Firstpage
    3422
  • Lastpage
    3425
  • Abstract
    A PET employing Geiger-mode avalanche photodiode (GAPD) has been designed and developed in our laboratory for simultaneous human brain PET-MR imaging. The purpose of this study is to evaluate the effect of temperature on the performance of the brain PET. The PET gantry including LYSO and GAPD array were placed in a temperature controlled chamber. All electronics including preamplifiers were located outside the chamber to minimize the temperature effect. Energy resolution and photo-peak position of all channels of the brain PET were measured. Count rates of the PET were also measured using 2 different Schemes: fixed energy window and adjusted energy window. All measurement was performed at 10°C ~ 40°C with 5°C step. Hot-rod phantom was acquired at 10°C, 25°C and 40°C. The energy resolution was degraded from 14% to 30% as the temperature raised. The photo-peak position the coincidence count rates were respectively decreased from 1314 ch to 560 ch, from 2.5 kcps to 0.9 kcps as the temperature raised. When the energy window was adjusted to the photo-peak position, the rates were stable from 10°C to 35°C. In hot-rod phantom images acquired at 10°C and 25°C, the rods down to a diameter of 3.5 mm were clearly resolved. However the phantom image acquired at 40 °C demonstrated noticeable degradation in image quality. Future study is being conducted to optimize the adjustable window to obtain stable performance of PET system using GAPD as a function of temperature.
  • Keywords
    Geiger counters; avalanche photodiodes; biomedical MRI; biomedical electronics; brain; phantoms; positron emission tomography; preamplifiers; GAPD array; Geiger-mode avalanche photodiode; LYSO array; adjusted energy window; electronics; energy resolution; fixed energy window; hot-rod phantom; human brain PET-MRI; image quality; photo-peak position; preamplifiers; size 3.5 mm; temperature 10 degC to 40 degC; temperature controlled chamber; temperature effect; Positron emission tomography; Temperature measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE
  • Conference_Location
    Valencia
  • ISSN
    1082-3654
  • Print_ISBN
    978-1-4673-0118-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2011.6152623
  • Filename
    6152623