• DocumentCode
    3329131
  • Title

    A comparative study of space charge effects on corona current using an indoor corona cage and a monopolar test line

  • Author

    Lekganyane, M.J. ; Ijumba, N.M. ; Britten, A.C.

  • Author_Institution
    High Voltage Direct Current Centre, Univ. of KwaZulu-Natal, Durban
  • fYear
    2007
  • fDate
    16-20 July 2007
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    The effect of space charge was investigated through corona current measurements. The tests were carried out in an indoor corona cage with and without aluminium foil cover, and on a monopolar test line with a high speed fan to simulate and assess the effect of wind on the space charge. The results obtained demonstrated that the corona current in the cage and the test line is more dependent on conductor voltage and resistance of the air gap. It has also been shown that the blowing of the wind on a test line conductor and the assisted draining away of charge carriers from the corona cage gap had the effect of reducing corona current.
  • Keywords
    conductors (electric); corona; space charge; air gap resistance; conductor voltage; corona current; indoor corona cage; monopolar test line; space charge effects; Africa; Charge carriers; Conductors; Corona; Current measurement; Geometry; HVDC transmission; Space charge; Testing; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Engineering Society Conference and Exposition in Africa, 2007. PowerAfrica '07. IEEE
  • Conference_Location
    Johannesburg
  • Print_ISBN
    978-1-4244-1477-2
  • Electronic_ISBN
    978-1-4244-1478-9
  • Type

    conf

  • DOI
    10.1109/PESAFR.2007.4498035
  • Filename
    4498035