Title :
Evaluation of a cardiac SPECT system using a common set of solid-state detectors for both emission and transmission scans and a ultras-low dose lead X-ray transmission line source
Author :
Bai, Chuanyong ; Babla, Hetal ; Kindem, Joel ; Conwell, Richard
fDate :
Oct. 24 2009-Nov. 1 2009
Abstract :
We developed a new cardiac SPECT system (X-ACT) with a low dose volume CT transmission-based attenuation correction (AC). Three solid-state detectors are configured to form a triple-head system for emission scans and reconfigured to form a large 27¿ (69 cm) field-of-view (FOV) detector arc for transmission scans. The transmission line source is the collimated fluorescence X-ray emitted from a lead target when the lead target is fluxed by a narrow X-ray beam from an X-ray tube. High quality transmission scans can be completed in as short as one minute with insignificant patient dose (~5 ¿Sv). For evaluation, we scanned an anthropomorphic phantom with a uniform cardiac insert and the same anthropomorphic phantom with one 60° full defect and one 45° 50% defect in the cardiac insert. We also scanned an ACR phantom and a uniform cylindrical phantom. Results showed that image uniformity and defect contrast were improved by AC in the anthropomorphic phantom studies as compared to without AC (NAC). The inferior to anterior wall ratio and the septal to lateral wall ratio were 0.99 and 1.16 before and 1.02 and 1.00 after AC. The defect contrast of the full and 50% defect was 0.528 and 0.156 before and 0.628 and 0.173 after AC. The ACR phantom images with AC showed correction of the bowing effect due to attenuation in the NAC images. The reconstructed attenuation coefficient of water at 140 keV was 0.154±0.003/cm and 0.157±0.002/cm in the liver and cardiac regions of the anthropomorphic phantom, and 0.150±0.003/cm in the uniform region of the ACR phantom and the uniform cylindrical phantom. In conclusion, the X-ACT system generated accurate attenuation maps with one-minute transmission scans. Phantom studies showed that AC improved image quality and quantification over NAC.
Keywords :
X-ray detection; X-ray emission spectra; X-ray tubes; cardiology; image reconstruction; liver; medical image processing; phantoms; single photon emission computed tomography; ACR phantom; X-ray tube; anthropomorphic phantom; cardiac SPECT system; collimated fluorescence X-ray; defect contrast; electron volt energy 140 keV; emission scans; field-of-view detector; image reconstruction; image uniformity; inferior-to-anterior wall ratio; liver; low dose volume CT transmission-based attenuation correction; narrow X-ray beam; reconstructed attenuation coefficient; septal-to-lateral wall ratio; solid-state detectors; transmission Scans; ultras-low dose lead X-ray transmission line source; uniform cylindrical phantom; Anthropomorphism; Attenuation; Collimators; Computed tomography; Fluorescence; Imaging phantoms; Solid state circuits; Transmission lines; X-ray detection; X-ray detectors; Attenuation Correction; Cardiac SPECT; Fluorescence X-ray Transmission Source; SolidState Detector;
Conference_Titel :
Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE
Conference_Location :
Orlando, FL
Print_ISBN :
978-1-4244-3961-4
Electronic_ISBN :
1095-7863
DOI :
10.1109/NSSMIC.2009.5401832