DocumentCode
3330248
Title
A preliminary study of image reconstruction from low-dose data in dedicated breast CT
Author
Bian, Junguo ; Han, Xiao ; Yang, Kai ; Sidky, Emil Y. ; Boone, John M. ; Pan, Xiaochuan
Author_Institution
Depts. of Radiol., Univ. of Chicago, Chicago, IL, USA
fYear
2011
fDate
23-29 Oct. 2011
Firstpage
2566
Lastpage
2568
Abstract
Interest exists in developing tomosynthesis machines and dedicated CT scanners for providing 3D images of breasts. Prototypes of dedicated breast CT scanners have been built and are under evaluation. In these scanners, analytic algorithms such as FDK are currently used for image reconstruction, which generally require data collected at a large number of views over a circular-scanning configuration. Imaging dose to patients is an important concern in breast CT. The current breast CT is designed to deliver about the same total imaging dose as that of a typical two-view mammography exam. This limited total exposure is distributed over a large number of views, thus resulting low-SNR data and noisy images. As breast-tissue contrast is relatively low, high noise level in images can render the tissue-contrast-based diagnosis difficult. Results from both academia and industry in developing iterative algorithms for image reconstruction from diagnostic CT data seem to indicate that they may yield images of higher quality than FDK from low-SNR data. In this work, we have investigated optimization-based iterative algorithms for image reconstruction from low-SNR data in breast CT. We have acquired both physical phantom and patient data for evaluating the utility of breast CT scanner. We formulated the reconstruction problem as a constrained minimization of the image total variation (TV), and used algorithms based upon the ASD-POCS scheme to solve the optimization problem. Using the algorithms developed, we reconstructed images from the phantom and patient data. Because the FDK algorithm is currently used clinically for image reconstruction in breast CT, images reconstructed with the proposed algorithms are compared with those obtained with the FDK algorithm. Results of these studies suggest that optimization-based algorithms may potentially improve image quality over the FDK algorithm for low-SNR breast-CT data.
Keywords
biological organs; cancer; computerised tomography; dosimetry; gynaecology; image denoising; image reconstruction; mammography; medical image processing; minimisation; phantoms; 3D imaging; breast-tissue contrast; dedicated breast CT scanners; high noise level; image reconstruction; low-SNR breast-CT data; low-dose data; optimization-based iterative algorithms; physical phantom; tissue-contrast-based diagnosis; tomosynthesis machines; total imaging dosimetry; two-view mammography; Computed tomography; Reconstruction algorithms; Signal to noise ratio;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE
Conference_Location
Valencia
ISSN
1082-3654
Print_ISBN
978-1-4673-0118-3
Type
conf
DOI
10.1109/NSSMIC.2011.6152692
Filename
6152692
Link To Document