    Cone-beam CT sequence scan reconstruction with improved dose usage and scan coverage

  • Author

    Grimmer, Rainer ; Berkus, Timo ; Oelhafen, Markus ; Kunz, Patrik ; Kachelrieß, Marc

  • Author_Institution
    Inst. of Med. Phys. (IMP), Univ. of Erlangen-Nurnberg, Erlangen, Germany
  • fYear
    2009
  • fDate
    Oct. 24 2009-Nov. 1 2009
  • Firstpage
    3759
  • Lastpage
    3763
  • Abstract
    For circular cone-beam CT often one scan covers not the complete z-range of interest. If this is the case two or more circle scans are made. These sequence scans are typically reconstructed by separately reconstructing each circle scan followed by combining the resulting partial volumes. This image-based concatenation method uses only those data that are needed for each partial volume, the contribution of rays to neighboring volumes are ignored, redundancies are not used, and dose is wasted. Therefore an algorithm that uses all rays that run through a voxel by appropriately weighting the rays followed by filtered backprojection was developed and evaluated. This leads to improved dose usage and increases the overlap region of neighboring volumes, potentially leading to reduced artifacts in this region. Alternatively, our approach allows to increase the table increment between adjacent circle acquisitions, and thereby the scan coverage, without impairing image quality or increasing dose. To evaluate our method we use the geometry of the Varian OBI flat panel detector CT scanner. Simulated and measured data are processed at varying table increment values and an evaluation of image noise, spatial resolution and artifacts has been performed. The method shows good image quality on simulated phantom data as well as on clinical patient data. In this paper the algorithm demonstrates its ability to extend the z-range of sequence scans and to improve the image quality in the overlap region and turns out to be usable on devices in the clinical practice.
  • Keywords
    computerised tomography; image denoising; image reconstruction; image sequences; medical image processing; CT sequence scan reconstruction; Varian OBI flat panel detector; adjacent circle acquisitions; circular cone-beam CT; dose usage; extended z-range; filtered backprojection; image artifacts; image noise; image quality; image-based concatenation method; partial volume; scan coverage; simulated phantom data; spatial resolution; Computed tomography; Detectors; Geometry; Image quality; Image reconstruction; Noise measurement; Nuclear and plasma sciences; Performance evaluation; Radio frequency; Spatial resolution; Cone-beam Computed tomography (CBCT); Extended z-Range; Noise reduction; Sequence Scan;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE
  • Conference_Location
    Orlando, FL
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-3961-4
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2009.5401883
  • Filename
    5401883