• DocumentCode
    3330957
  • Title

    Performance evaluation of the LabPET12, a large axial FOV APD-based digital PET scanner

  • Author

    Bergeron, M. ; Cadorette, J. ; Bureau-Oxton, C. ; Beaudoin, J.-F. ; Tètrault, M.C. ; Leroux, J.-D. ; Lepage, M.D. ; Robert, G. ; Fontaine, R. ; Lecomte, R.

  • Author_Institution
    Dept. of Nucl. Med. & Radiobiol., Univ. de Sherbrooke, Sherbrooke, QC, Canada
  • fYear
    2009
  • fDate
    Oct. 24 2009-Nov. 1 2009
  • Firstpage
    4017
  • Lastpage
    4021
  • Abstract
    The LabPET12 is the latest version of LabPET¿ avalanche photodiode (APD)-based digital scanners, having an 11.4 cm axial field of view and 9216/4608 crystals/electronic readout channels to achieve high sensitivity and count rate performance, while preserving the same very high spatial resolution. Its performance characteristics have been thoroughly investigated largely based on the new NEMA NU4 - 2008 small animal PET standard. Average energy resolution is 20±3% for LYSO and 19±3% for LGSO. After timing alignment, the overall FWHM timing resolution is 7.1/8.3/9.2 ns for LYSO/LYSO, mixed and LGSO/LGSO coincidences. Imaging performance was assessed using various energy windows with lower threshold from 100 to 350 keV. Sensitivity varied from 8 to 2.8%, between 100 and 350 keV. With the lower threshold set at 200 keV, peak NEC count rates were 449 kcps at 66 MBq and 179 kcps at 81 MBq for the mouse and rat NEMA phantoms, respectively. Two acquisition modes were investigated, a high sensitivity and high resolution mode. Whole-body static images of mice were obtained with Na18F. In conclusion, the LabPET12 provides excellent dynamic performance with shorter imaging time or lower injected radioactivity while achieving the same exquisite spatial resolution as the LabPET4 and LabPET8 scanners.
  • Keywords
    avalanche photodiodes; image resolution; particle detectors; phantoms; positron emission tomography; solid scintillation detectors; APD-based digital PET scanner; FWHM timing resolution; LGSO; LYSO; LabPET12; NEMA NU4-2008 small animal PET standard; NEMA phantoms; Na18F; avalanche photodiode; electronic readout channels; injected radioactivity; timing alignment; whole-body static images; Animals; Avalanche photodiodes; Crystals; Energy resolution; Imaging phantoms; Mice; National electric code; Positron emission tomography; Spatial resolution; Timing; Avalanche photodiodes; PET instrumentation; Performance evaluation; Positron emission tomography;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE
  • Conference_Location
    Orlando, FL
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-3961-4
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2009.5401915
  • Filename
    5401915