    Comparison of NEMA NU 4-2008 vs NEMA NU 2-2001 for the performance evaluation of the microPET R4 system

  • Author

    Popota, F.D. ; Aguiar, P. ; Fernandez, Y. ; Lois, C. ; Pareto, D. ; Ros, D. ; Pavia, J. ; Gispert, J.D.

  • Author_Institution
    Inst. d´´ Alta Tecnol.-PRBB, CRC Corporacio Sanitaria, Barcelona, Spain
  • fYear
    2009
  • fDate
    Oct. 24 2009-Nov. 1 2009
  • Firstpage
    2706
  • Lastpage
    2709
  • Abstract
    Positron Emission Tomography (PET) techniques have gained an important role in the diagnosis of human diseases as well as for pharmaceutical and biomedical research. In order to best optimize their capabilities, evaluation of their performance has to be achieved through standardized methodology from specific standards. The aim of this work was to assess the performance evaluation of the microPET R4 system for imaging rodents according to the new NEMA NU 4-2008 standards and compare it against its previous evaluation according the adapted clinical NEMA NU 2-2001. All measurements were made for an energy window of 350-650 keV. Spatial resolution of 2.12 mm FWHM in the radial direction, 2.66 mm FWHM in the tangential direction and 2.23 mm FWHM in the axial direction was measured in the centre of the axial FOV. Scatter fraction for mouse and rat phantoms were found to be 9.5% and 22% respectively. The maximum noise-equivalent count rate (NECR) was 110 kcps at 121.3 MBq for the rat phantom 287 kcp at 129.8 MBq for the mouse phantom. The absolute sensitivity of the scanner was found to be 1.66% at the centre of the field of view.
  • Keywords
    image reconstruction; image resolution; medical image processing; phantoms; positron emission tomography; NEMA NU 2-2001 standards; NEMA NU 4-2008 standards; axial direction; electron volt energy 350 keV to 650 keV; image quality phantom reconstruction; microPET R4 system; mouse phantoms; noise-equivalent count rate; performance evaluation; positron emission tomography; radioactivity 121.3 MBq; rat phantoms; rodents; spatial resolution; tangential direction; Biomedical imaging; Biomedical measurements; Diseases; Humans; Imaging phantoms; Mice; Optimization methods; Pharmaceuticals; Positron emission tomography; Rodents;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE
  • Conference_Location
    Orlando, FL
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-3961-4
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2009.5401976
  • Filename
    5401976