    Examining the mean frequency of myoelectric signals produced by dynamic muscle contractions

  • Author

    MacIsaac, D.T. ; Parker, P.A. ; Scott, R.N.

  • Author_Institution
    New Brunswick Univ., Fredericton, NB, Canada
  • Volume
    5
  • fYear
    1998
  • fDate
    28 Oct-1 Nov 1998
  • Firstpage
    2650
  • Abstract
    The mean frequency of the power spectrum of a myoelectric signal is an accepted index for monitoring fatigue in static contractions. There is, however, indication that it may be a useful index even in dynamic contractions. The purpose of this investigation was to examine this possibility. Results obtained while comparing mean frequency data produced from static and dynamic contractions reveal that it may be feasible to use mean frequency as an index for monitoring fatigue in dynamic contractions
  • Keywords
    biomechanics; electromyography; medical signal processing; spectral analysis; time-frequency analysis; computer simulation; dynamic muscle contractions; fatigue monitoring index; mean frequency; myoelectric signals; power spectrum; short time FT; static contractions; time-frequency transform; white Gaussian signal; Amplitude modulation; Computer simulation; Fatigue; Monitoring; Muscles; Niobium; Production; Signal processing; Time frequency analysis; Time measurement;