DocumentCode :
3332615
Title :
Hybrid Power Line Conditioner Based on Two Parallel Converters Topology
Author :
Montero, M.-I.M. ; Cadaval, Enrique Romero ; Gonzalez, F.B.
fYear :
2007
fDate :
May 29 2007-June 1 2007
Firstpage :
1
Lastpage :
7
Abstract :
A new hybrid power line conditioner is proposed in this paper. It is formed by an active conditioner in parallel with a hybrid conditioner composed by an active filter in series to one or more passive filters. This topology allows the reduction of the inverters rating, constituting an effective solution in high power levels where classical power filters can not be used. The conditioner operates properly in three-phase four-wire systems reducing the harmonic distortion and/or unbalance and attaining unity displacement power factor. Experimental results are included for testing the topology and its control.
Keywords :
active filters; harmonic distortion; passive filters; power conversion harmonics; power factor; power harmonic filters; active filter; harmonic distortion; hybrid power line conditioner; parallel converters topology; passive filters; three-phase four-wire systems; unity displacement power factor; Active filters; Frequency; Hybrid power systems; Inverters; Passive filters; Power filters; Power harmonic filters; Power system harmonics; Reactive power; Topology; Active filter; hybrid filter; multiconverter topology; power line conditioner;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Compatibility in Power Electronics, 2007. CPE '07
Conference_Location :
Gdansk
Print_ISBN :
1-4244-1055-X
Electronic_ISBN :
1-4244-1055-X
Type :
conf
DOI :
10.1109/CPE.2007.4296510
Filename :
4296510
Link To Document :
بازگشت