    Time resolution for scattered and unscattered coincidences in a TOF PET scanner

  • Author

    Conti, Maurizio ; Rothfuss, Harold

  • Author_Institution
    Mol. Imaging, Siemens Healthcare, Knoxville, TN, USA
  • fYear
    2009
  • fDate
    Oct. 24 2009-Nov. 1 2009
  • Firstpage
    2629
  • Lastpage
    2635
  • Abstract
    Time resolution is a key parameter in the performance of a TOF PET scanner, and it is usually measured in the system with unscattered data and used as the width of the TOF kernel in reconstruction. In fact, the time distribution of detected coincidence events is a function of the energy of the detected photons, and trues and scatter events have different time distributions. While the reconstruction TOF kernel should match the true, unscattered data, the scatter simulation used for scatter correction should match the time distribution of the scatter data. This work, using experimental measurements and Monte Carlo simulation, confirmed that the time resolution in a PET scanner is dependent on the energy of the detected photon pair. Moreover, it was observed that trues, single and multiple scatter in general have different time distributions. The FWHM of the time distribution of trues and scatter in different configurations of phantoms and energy threshold were evaluated. The width of the time distribution for scatter was observed to be much larger than for trues, particularly because of the effect of multiple scatter, if low energy thresholds are used. On the other hand, the use of a high energy threshold (for example, 435 keV) reduces the timing FWHM of scatter and the weight of multiple scatter, and allows the use of single scatter simulation as a good approximation of the data time distribution in a realistic PET scan.
  • Keywords
    Monte Carlo methods; coincidence techniques; particle spectrometers; positron emission tomography; time of flight spectroscopy; Monte Carlo simulation; TOF PET scanner; TOF kernel width; coincidence event time distribution; detected photon pair energy; reconstruction TOF kernel; scatter correction; scatter event time distributions; scatter simulation; scattered coincidence event; time distribution FWHM; time resolution; unscattered coincidences; Electromagnetic scattering; Energy measurement; Energy resolution; Event detection; Imaging phantoms; Kernel; Particle scattering; Positron emission tomography; Time measurement; Timing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE
  • Conference_Location
    Orlando, FL
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-3961-4
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2009.5402003
  • Filename
    5402003