• DocumentCode
    3333550
  • Title

    Treatment of skin infections with DC operated afterglow air plasma jet

  • Author

    Kolb, J.F. ; Heller, L.C. ; Singh, T. ; Bowman, A.M. ; Swanson, R.J. ; Schoenbach, K.H.

  • Author_Institution
    Frank Reidy Res. Center for Bioelectrics, Old Dominion Univ., Norfolk, VA, USA
  • fYear
    2010
  • fDate
    20-24 June 2010
  • Firstpage
    1
  • Lastpage
    1
  • Abstract
    Summary form only given. We have developed a non-thermal plasma jet, which is generated with a dc voltage from ambient air. By flowing air through the channel of a microhollow cathode discharge geometry at rates of 7-15 Ltr/min, a 10-20-mm long afterglow plasma plume is observed. The temperature in this expelled afterglow plasma reaches values that are close to room temperature at a distance of 5 mm from the discharge origin. Emission spectra show that atomic oxygen, hydroxyl ions and various nitrogen compounds are generated in the discharge and are driven out with the gas flow. These radicals are considered highly effective in the decontamination and sterilization of surfaces. We have investigated the effectiveness of this microplasma jet against notoriously difficult to treat yeast infections. In an in vitro study, complete eradication of Candida kefyr (a model for Candida albicans - the most common yeast infection) could be achieved with an exposure of 90 seconds at distances of 10 mm and more. Other pathogens that were tested, also respond well. The safety of the treatment was studied by an in vivo skin model. The exposure of healthy skin to the plasma jet, when using the same treatment parameters as for the in vitro studies, and even a treatment with a ten times higher dose, did not result in any damage. Possible interaction mechanisms were investigated. Treatment parameters, such as the penetration depth of radicals into skin, were studied with skin substitutes.
  • Keywords
    afterglows; air; microorganisms; oxygen; patient treatment; plasma applications; plasma jets; plasma temperature; skin; sterilisation (microbiological); Candida albicans; O2; afterglow plasma plume; afterglow plasma temperature; air flow; dc operated afterglow air plasma jet; emission spectra; gas flow; interaction mechanism; microhollow cathode discharge geometry; microplasma jet; nonthermal plasma jet; radical penetration depth; size 10 mm to 20 mm; skin infection; skin model; surface sterilization; yeast infection; Atomic measurements; Cathodes; DC generators; Fungi; Geometry; In vitro; Nitrogen; Plasma temperature; Skin; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Plasma Science, 2010 Abstracts IEEE International Conference on
  • Conference_Location
    Norfolk, VA
  • ISSN
    0730-9244
  • Print_ISBN
    978-1-4244-5474-7
  • Electronic_ISBN
    0730-9244
  • Type

    conf

  • DOI
    10.1109/PLASMA.2010.5534248
  • Filename