DocumentCode
3334152
Title
Soft X-ray diagnostics of density and dynamics of dodecane sprays
Author
Robert, Eric ; Dozias, Sébastien ; Cachoncinlle, Christophe ; Pouvesle, Jean Michel
Author_Institution
CNRS, Polytech ´´Orleans, Orléans, France
fYear
2010
fDate
20-24 June 2010
Firstpage
1
Lastpage
1
Abstract
Summary form only given. The optimization of vehicle engine injectors has been and is still today a critical issue for the reduction of fuel consumption, the limitation of air pollutant release and the development of alternative fuels. An extended panel of diagnostic techniques is applied for the spray atomisation description in connection with a large effort in modelling works. Dealing with the near nozzle region, i.e. the dense region of the spray, only the X-ray absorption technique was shown to be able to provide valuable data. Very significant improvement of this high density region characterization was recently achieved using unique features of synchrotron X-rays.In this contribution, the development of a table top flash soft X-ray source emitting twenty nanosecond duration X-ray pulses with an equivalent energy of 8.3 keV is described together with its use for the density and dynamics diagnostics of pure dodecane and cerium doped dodecane sprays expanding through serial diesel injectors set in a high pressure chamber inflated up to 30 bars. Time resolved flash X-ray radiography using a high sensitivity Andor X-ray camera was performed 80 cm away from the X-ray spot by averaging the absorption of the spray over a few thousands of injection events synchronized with X-ray shots. While providing less accurate data than reference highly monochromatic and space resolved synchrotron studies, our work allow for the determination of the near nozzle spray density together with the spray angle and propagation velocity in a large range of operating conditions including caviting and non caviting injectors, various chamber or rail pressures, and to the best of our knowledge the first experiments on pure, non cerium seeded, dodecane sprays. The radiograph analysis first confirms that strong mixing between the liquid fuel and ambient gas occurs over the first millimetres downstream the nozzle tip which was up today not fully considered or inferred from the modelling. Second- the spray exhibits two distinct density components propagating with different velocities. Finally, the spray leading edge mean velocity was measured to decrease from 250 m.s"1 down to 140 m.s"1, as the nitrogen pressure chamber increases from one bar to 25 bars.
Keywords
nitrogen; plasma X-ray sources; plasma density; plasma diagnostics; plasma pressure; plasma transport processes; N2; X-ray absorption technique; X-ray pulses; air pollutant; cerium doped dodecane sprays; diagnostic techniques; dodecane spray dynamics; electron volt energy 8.3 keV; fuel consumption; high density region characterization; high pressure chamber; high sensitivity Andor X-ray camera; nitrogen pressure chamber; nozzle spray density; propagation velocity; radiograph analysis; soft X-ray diagnostics; spray atomisation; spray leading edge mean velocity; synchrotron X-rays; time resolved flash X-ray radiography; vehicle engine injector; Bars; Cerium; Diesel engines; Electromagnetic wave absorption; Fuels; Radiography; Spraying; Synchrotrons; Vehicle dynamics; Vehicles;
fLanguage
English
Publisher
ieee
Conference_Titel
Plasma Science, 2010 Abstracts IEEE International Conference on
Conference_Location
Norfolk, VA
ISSN
0730-9244
Print_ISBN
978-1-4244-5474-7
Electronic_ISBN
0730-9244
Type
conf
DOI
10.1109/PLASMA.2010.5534289
Filename
5534289