• DocumentCode
    3334338
  • Title

    Droplet volume adjustable microinjectors using a microheater array

  • Author

    Kang, Tae Goo ; Cho, Young-Ha

  • Author_Institution
    Digital Nanolocomotion Center, Korea Adv. Inst. of Sci. & Technol., Daejeon, South Korea
  • fYear
    2003
  • fDate
    19-23 Jan. 2003
  • Firstpage
    690
  • Lastpage
    693
  • Abstract
    We present the design, fabrication and experimental results of the thermofluidic digital microinjectors, whose ejected droplet volumes are adjusted by the digital operation of a microheater array composed of four microheaters. We measured a life history of the microbubbles generated on the microheater array. The ejected droplet volume is adjusted as 1.4±0.5, 4.2±1.0, 6.0±1.3, 11.0±1.9 p/depending on the number of active microheaters. Thus, volume adjustable capability of the digital microinjectors has the potential to enhance a image quality as well as printing speed.
  • Keywords
    ink jet printers; microfluidics; digital operation; droplet volume adjustable microinjectors; ejected droplet volume; image quality; microbubbles; microheater array; printing speed; thermofluidic digital microinjectors; volume adjustable capability; Gray-scale; Heat transfer; Image quality; Ink; Microinjection; Printing; Pulse modulation; Resistors; Signal generators; Thermal expansion;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Micro Electro Mechanical Systems, 2003. MEMS-03 Kyoto. IEEE The Sixteenth Annual International Conference on
  • ISSN
    1084-6999
  • Print_ISBN
    0-7803-7744-3
  • Type

    conf

  • DOI
    10.1109/MEMSYS.2003.1189843
  • Filename
    1189843