• DocumentCode
    3334961
  • Title

    Justification for AC vs. DC drive systems

  • Author

    Berthiaume, Denis

  • Author_Institution
    Ind. James Maclaren Inc., Thurso, Que., Canada
  • fYear
    1991
  • fDate
    3-7 June 1991
  • Firstpage
    234
  • Lastpage
    238
  • Abstract
    It is pointed out that AC variable-speed drives are seeing more widespread use in the pulp and paper industry. This is due to the reliability and low cost of the AC induction motor, combined with the recently improved economy and performance of AC drives. It is noted that, even though the up-front cost of an AC drive control, is greater than that of the DC drive, there are many factors to consider that can quickly make up the difference. Conservative data are presented which indicate a 17% savings as a percentage of total system and installation cost using AC drives. Some end users have experienced up to 30% savings.<>
  • Keywords
    paper industry; variable speed drives; AC induction motor; AC variable-speed drives; DC drive; drive control; paper industry; pulp industry; AC motors; Costs; DC motors; Induction motors; Isolation technology; Milling machines; Power transformer insulation; Reactive power; Variable speed drives; Ventilation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulp and Paper Industry Technical Conference, 1991., Conference Record of 1991 Annual
  • Conference_Location
    Montreal, Quebec, Canada
  • Type

    conf

  • DOI
    10.1109/PAPCON.1991.239643
  • Filename
    239643