Notice of Retraction
Coagulants Optimization of Low Turbidity Water Treatment in Feedwater Plant
Author
Hui Liu ; Di Guan ; Zhen Zhang
Author_Institution
Coll. of Aerosp. & Civil Eng., Harbin Eng. Univ., Harbin, China
fYear
2011
fDate
10-12 May 2011
Firstpage
1
Lastpage
3
Abstract
Notice of Retraction
After careful and considered review of the content of this paper by a duly constituted expert committee, this paper has been found to be in violation of IEEE´s Publication Principles.
We hereby retract the content of this paper. Reasonable effort should be made to remove all past references to this paper.
The presenting author of this paper has the option to appeal this decision by contacting TPII@ieee.org.
This research aimed to determine the organic and turbidity removal efficiencies of different coagulants to raw water with low temperature and turbidity. The experiments employed poly aluminum chloride (PAC), poly aluminum ferric chloride (PAFC), poly ferric chloride (PFC) and poly aluminum ferric chloride collosol (AFO) as coagulants to simulate the treatment processing. The results indicated that the optimum doses of selected coagulants were identified at 30mg/L for PAC, 25mg/L for PAFC, 30mg/L for PFC and 35mg/L for AFO by the experiments of impurities removal. Compared the impurities removal rates of low turbidity water, the PAC obtained the greater treatment efficiency.
After careful and considered review of the content of this paper by a duly constituted expert committee, this paper has been found to be in violation of IEEE´s Publication Principles.
We hereby retract the content of this paper. Reasonable effort should be made to remove all past references to this paper.
The presenting author of this paper has the option to appeal this decision by contacting TPII@ieee.org.
This research aimed to determine the organic and turbidity removal efficiencies of different coagulants to raw water with low temperature and turbidity. The experiments employed poly aluminum chloride (PAC), poly aluminum ferric chloride (PAFC), poly ferric chloride (PFC) and poly aluminum ferric chloride collosol (AFO) as coagulants to simulate the treatment processing. The results indicated that the optimum doses of selected coagulants were identified at 30mg/L for PAC, 25mg/L for PAFC, 30mg/L for PFC and 35mg/L for AFO by the experiments of impurities removal. Compared the impurities removal rates of low turbidity water, the PAC obtained the greater treatment efficiency.
Keywords
coagulation; turbidity; water supply; water treatment; coagulants optimization; feedwater plant; low turbidity water treatment; poly aluminum chloride; poly aluminum ferric chloride collosol; poly ferric chloride; Aluminum; Coagulation; Impurities; Production; Reservoirs; Water pollution;
fLanguage
English
Publisher
ieee
Conference_Titel
Bioinformatics and Biomedical Engineering, (iCBBE) 2011 5th International Conference on
Conference_Location
Wuhan
ISSN
2151-7614
Print_ISBN
978-1-4244-5088-6
Type
conf
DOI
10.1109/icbbe.2011.5780938
Filename
5780938
Link To Document