• DocumentCode
    3335355
  • Title

    Discharge lamp harmonic interaction study by Monte Carlo simulation and experimental measurements

  • Author

    Mesas, J.J. ; Sainz, L. ; Ferrer, A.

  • Author_Institution
    Dept. of Electr. Eng., ETSEIB-UPC, Barcelona
  • fYear
    2009
  • fDate
    18-20 March 2009
  • Firstpage
    303
  • Lastpage
    308
  • Abstract
    The growing presence of discharge lamps in power distribution systems has increased the harmonic distortion in these systems. The paper studies the magnetic ballast discharge lamp modelization with and without harmonic interaction. The supply harmonic voltage influence on lamp behavior is analyzed by Monte Carlo simulation. The results are validated with experimental measurements.
  • Keywords
    Monte Carlo methods; discharge lamps; harmonic distortion; lamp accessories; Monte Carlo simulation; harmonic distortion; magnetic ballast discharge lamp; power distribution system; Electron tubes; Electronic ballasts; Fault location; Fluorescent lamps; Harmonic analysis; High intensity discharge lamps; Power distribution; Power measurement; Power system harmonics; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Engineering, Energy and Electrical Drives, 2009. POWERENG '09. International Conference on
  • Conference_Location
    Lisbon
  • Print_ISBN
    978-1-4244-4611-7
  • Electronic_ISBN
    978-1-4244-2291-3
  • Type

    conf

  • DOI
    10.1109/POWERENG.2009.4915168
  • Filename
    4915168