DocumentCode :
3335477
Title :
Precise power and energy measurement
Author :
Milosavljevic, D.M. ; Milenkovic, V.V. ; Radenkovic, V.D.
Author_Institution :
EI Holding, Nis, Yugoslavia
Volume :
2
fYear :
1999
fDate :
1999
Firstpage :
637
Abstract :
In this paper a realization of a precise electrical power and energy meter is presented. The fundamental of the described solution is an application of the “time division” multiplier. In this paper the technical improvements are described in order to achieve a higher accuracy. The achieved accuracy is better than 10-4 for sinusoidal input signals with the frequency of 50 Hz
Keywords :
current transformers; energy measurement; power measurement; power meters; 50 Hz; current transformer; energy meter; power meter; precise energy measurement; precise power measurement; pulse amplitude modulator; sinusoidal input signals; time division multiplier; Energy measurement; Frequency conversion; Home appliances; Power engineering and energy; Power measurement; Strontium; Switches; Switching converters; Voltage; Watthour meters;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Telecommunications in Modern Satellite, Cable and Broadcasting Services, 1999. 4th International Conference on
Conference_Location :
Nis
Print_ISBN :
0-7803-5768-X
Type :
conf
DOI :
10.1109/TELSKS.1999.806291
Filename :
806291
Link To Document :
بازگشت