  • Abstract
    While nuclear methods find application in plant biology there are very limited amount of instrumentation that is geared to the unique challenges that plant biology presents. Mostly researchers are utilizing devices created for clinical and preclinical imaging. The majority of the biologically significant elements involved in plant formation have positron emitting isotopes, making positron emission tomography a naturally fitting imaging modality. One particular caveat in using PET instrumentation in plant imaging is extremely small thickness of the leaf as an annihilation medium for emitted positrons. For positron energies around 1 MeV (as in case of C-11), about 1 mm of water equivalent material is required for positron conversion, so most of the positrons would not annihilate inside the leaf, therefore limiting both sensitivity and spatial resolution of the imaging system. In this work we made an attempt of determining whether direct imaging of positrons could be beneficial in plant biology studies. We compared performance of direct positron detector with a planar PET system. Detection efficiency ratio of ~650 in favor of direct positron detection system was measured. Direct comparison of spatial resolutions yielded comparable numbers for a setup, when a phantom was placed directly onto the entrance window of the positron detector. We also determined quick deterioration of spatial resolution as a function of source to detector distance. The last observation makes it necessary to maintain close proximity of the object to the detector, but this condition can be met in plant biology study.
  • Keywords
    botany; phantoms; positron emission tomography; radiation detection; PET instrumentation; annihilation medium; detection efficiency ratio; direct positron detection system; direct positron detector; fitting imaging modality; imaging system; leaf; phantom; planar PET system; plant biology; plant formation; plant imaging research; positron conversion; positron emission tomography; positron emitting isotopes; positron energies; preclinical imaging; spatial resolution; water equivalent material; Biological materials; Chemical elements; Detectors; Fitting; Imaging phantoms; Instruments; Isotopes; Plants (biology); Positron emission tomography; Spatial resolution;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE
  • Conference_Location
    Orlando, FL
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-3961-4
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2009.5402250
  • Filename
    5402250