Title :
Boiler efficiency analysis using direct method
Author :
Shah, Sunit ; Adhyaru, D.M.
Abstract :
Real-time data of boiler thermal efficiency can really reflect the boiler operation condition, heat generation and heat loss. Performance of the boiler, like efficiency and evaporation ratio reduces with time, due to poor combustion, heat transfer fouling and poor operation and maintenance. Boiler efficiency can be also useful in analysis of boiler and can also be used in predictive maintenance of the boiler. How to reduce problems of the boiler efficiency real-time computations and be successful in calculating the boiler thermal efficiency on line are the main concern of operation departments of power systems. Using Heat Input-Output method plant people can evaluate quickly the efficiency of boilers using few parameters.
Keywords :
boilers; combustion; evaporation; heat transfer; preventive maintenance; boiler efficiency analysis; boiler operation condition; boiler thermal efficiency; combustion; direct method; evaporation ratio; heat generation; heat input-output method; heat loss; heat transfer fouling; power system operation department; predictive maintenance; Boilers; Combustion; Fuels; Heat transfer; Temperature measurement; Water heating; Boiler Efficiency; Input-Output Method; Real-Time;
Conference_Titel :
Engineering (NUiCONE), 2011 Nirma University International Conference on
Conference_Location :
Ahmedabad, Gujarat
Print_ISBN :
978-1-4577-2169-4
DOI :
10.1109/NUiConE.2011.6153313