Title :
Upgrade of Mini-DDL applied in the radiation field measurement
Author :
Han, Xiaoxue ; Zeng, Ming ; Xue, Tao ; Shao, Beibei ; Li, Juexin ; Li, Yuxiong
Author_Institution :
Dept. of Eng. Phys., Tsinghua Univ., Beijing, China
fDate :
Oct. 24 2009-Nov. 1 2009
Abstract :
Mini-DDL is a specific device designed for radiation field real-time monitoring, which has already been applied in NSRL, SSRF and BEPC. Although these applications have proved this device to be functional and helpful, users have presented some concrete proposals for improvement according to their usage experience. Based on brief review of the previous Mini-DDL, this paper introduce technologies which are applied to upgrade the Mini-DDL, including the OLED display and the FatFs module. The new version of Mini-DDL will offer more flexible data transfer interfaces, larger and various storage capacity, capable of running in more critical environment.
Keywords :
nuclear electronics; FatFs module; OLED display; flexible data transfer interfaces; miniDDL applied; radiation field measurement; radiation field real-time monitoring; Clocks; File systems; Flat panel displays; Hardware; Liquid crystal displays; Open source software; Organic light emitting diodes; Radiation monitoring; Synchrotron radiation; Universal Serial Bus;
Conference_Titel :
Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE
Conference_Location :
Orlando, FL
Print_ISBN :
978-1-4244-3961-4
Electronic_ISBN :
1095-7863
DOI :
10.1109/NSSMIC.2009.5402326