DocumentCode
333830
Title
Unstable frequency oscillations in a slow-response reheat-turbine generator
Author
Vournas, C.D.
Author_Institution
Electr. Energy Syst. Lab., Nat. Tech. Univ. of Athens, Greece
Volume
1
fYear
1999
fDate
31 Jan-4 Feb 1999
Firstpage
140
Abstract
This paper shows that governor rate limits may result in slow response that interacts with that of a reheat turbine to create unstable frequency oscillations. The origin of these oscillations is explained with a linear analogue, while nonlinear simulation shows that the oscillations evolve into a limit cycle due to gate limits. A control scheme to stabilize the frequency oscillations through control of the intercept valve is developed and tested in the paper
Keywords
frequency stability; oscillations; steam power stations; steam turbines; valves; boilers; frequency oscillations stabilisation; gate limits; governor rate limits; governors; intercept valve; limit cycle; linear analogue; long term dynamics; nonlinear simulation; reheat turbine; slow response; slow-response reheat-turbine generator; steam power plant; steam turbines; unstable frequency oscillations; Boilers; Frequency control; Power generation; Power system dynamics; Power system modeling; Power system stability; Power system transients; Stability analysis; Turbines; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Engineering Society 1999 Winter Meeting, IEEE
Conference_Location
New York, NY
Print_ISBN
0-7803-4893-1
Type
conf
DOI
10.1109/PESW.1999.747439
Filename
747439
Link To Document