DocumentCode
3340414
Title
Systematic study of the calibration and resolution of drift tubes for Muon tracking in the ATLAS experiment at the LHC
Author
Luise, S. Di
Author_Institution
Dipt. di Fis., Univ. Roma Tre, Rome, Italy
fYear
2009
fDate
Oct. 24 2009-Nov. 1 2009
Firstpage
1025
Lastpage
1027
Abstract
The Muon Spectrometer of the ATLAS experiment consists of three large air core toroidal magnets, one barrel and two end-caps. The bending power is about 3 and 5 Tm respectively. Tracking in the range |¿| < 2 is done with regular arrays of 3 cm diameter high pressure drift tubes, called MDT, arranged in three measurement stations. The aim of the experiment is a relative resolution of 10% at transverse momentum of 1 TeV/c. At this value, the resolution is limited by the detectors alignment and the single point resolution. The second should not exceed 80 ¿m per tube, averaged over the drift distance. The gas composition (93%Ar-7%CO2) and gain (2·104), chosen in order to limit the aging, makes the drift response function, r(t), highly non linear, thus it depends on temperature, pressure and local value of the magnetic field. An auto-calibration method has been developed to calculate from the data themselves the r(t) function and to extract the resolution function. This method has been extensively tested on a beam of high momentum muons to study systematic effects and the statistics needed to guarantee that the calibration error is indeed much smaller than the single point resolution. We describe the analysis of these data, and present the results on the convergence of the auto-calibration as a function of the track angular range, the number of tracks, the track fit quality requirements, the correlation between angle and position measurement, for both three and four tube layers.
Keywords
calibration; iterative methods; muon detection; position sensitive particle detectors; proportional counters; ATLAS muon spectrometer; LHC ATLAS experiment; air core toroidal magnets; argon-carbon dioxide gas mixture; autocalibration method; detector alignment; drift response function; drift tube calibration; drift tube resolution; high momentum muon; high pressure drift tubes; muon tracking; single point resolution; size 3 cm; Aging; Calibration; Detectors; Large Hadron Collider; Magnetic cores; Magnets; Mesons; Pressure measurement; Spectroscopy; Temperature dependence;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE
Conference_Location
Orlando, FL
ISSN
1095-7863
Print_ISBN
978-1-4244-3961-4
Electronic_ISBN
1095-7863
Type
conf
DOI
10.1109/NSSMIC.2009.5402437
Filename
5402437