DocumentCode :
3340480
Title :
Streamlined calibration of the ATLAS Muon Spectrometer precision chambers
Author :
Levin, Daniel S.
Author_Institution :
Dept. of Phys., Univ. of Michigan, Ann Arbor, MI, USA
fYear :
2009
fDate :
Oct. 24 2009-Nov. 1 2009
Firstpage :
1040
Lastpage :
1044
Abstract :
The ATLAS Muon Spectrometer is comprised of 1150 optically Monitored Drifttube Chambers (MDTs) containing 354,000 aluminum drift tubes. The chambers are configured in barrel and endcap regions. The momentum resolution required for the LHC physics reach (dp/p = 3% and 10% at 100 GeV and at 1 TeV respectively) demands rigorous MDT drift tube calibration with frequent updates. These calibrations (RT functions) convert the measured drift times to drift radii and are a critical component to the spectrometer performance. They are sensitive to the MDT gas composition: Ar 93%, CO2 7% at 3 bar, flowing through the detector at a rate of 100,000 l hr-1. We report on the generation and application of Universal RT calibrations derived from an inline gas system monitor chamber. Results from ATLAS cosmic ray commissioning data are included. These Universal RTs are intended for muon track reconstuction in the LHC startup phase.
Keywords :
drift chambers; muon detection; particle spectrometers; particle track visualisation; LHC startup phase; MDT gas composition; RT functions; aluminum drift tubes; drift radii; drift times; inline gas system monitor chamber; momentum resolution; muon spectrometer; muon track reconstuction; optically monitored drifttube chambers; universal RT calibrations; Aluminum; Argon; Calibration; Gas detectors; Large Hadron Collider; Mesons; Monitoring; Optical sensors; Physics; Spectroscopy;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE
Conference_Location :
Orlando, FL
ISSN :
1095-7863
Print_ISBN :
978-1-4244-3961-4
Electronic_ISBN :
1095-7863
Type :
conf
DOI :
10.1109/NSSMIC.2009.5402440
Filename :
5402440
Link To Document :