DocumentCode
334067
Title
Measurement of Tevatron extraction parameters and comparison of model to measurements
Author
Martens, M.A. ; Marriner, J. ; Holt, J.
Author_Institution
Fermi Nat. Accel. Lab., Batavia, IL, USA
Volume
1
fYear
1997
fDate
12-16 May 1997
Firstpage
72
Abstract
An accurate model of the half integer resonance extraction process in the Tevatron requires a knowledge of the extraction parameters such as the strengths of the 39th harmonic quadrupole and 0th harmonic octupole. This paper describes a series of experiments that determine the extraction parameters. Results of target wire scans, which measure the profile of the extracted beam, are then compared to the Tevatron model
Keywords
colliding beam accelerators; particle beam dynamics; particle beam extraction; proton accelerators; storage rings; synchrotrons; Tevatron extraction parameters; half integer resonance extraction process; harmonic octupole; harmonic quadrupole; target wire scans; Circuit topology; Integral equations; Laboratories; Lattices; Particle beams; Protons; RLC circuits; Resonance; Superconducting magnets; Wire;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1997. Proceedings of the 1997
Conference_Location
Vancouver, BC
Print_ISBN
0-7803-4376-X
Type
conf
DOI
10.1109/PAC.1997.749547
Filename
749547
Link To Document