Title :
Measurement of Tevatron extraction parameters and comparison of model to measurements
Author :
Martens, M.A. ; Marriner, J. ; Holt, J.
Author_Institution :
Fermi Nat. Accel. Lab., Batavia, IL, USA
Abstract :
An accurate model of the half integer resonance extraction process in the Tevatron requires a knowledge of the extraction parameters such as the strengths of the 39th harmonic quadrupole and 0th harmonic octupole. This paper describes a series of experiments that determine the extraction parameters. Results of target wire scans, which measure the profile of the extracted beam, are then compared to the Tevatron model
Keywords :
colliding beam accelerators; particle beam dynamics; particle beam extraction; proton accelerators; storage rings; synchrotrons; Tevatron extraction parameters; half integer resonance extraction process; harmonic octupole; harmonic quadrupole; target wire scans; Circuit topology; Integral equations; Laboratories; Lattices; Particle beams; Protons; RLC circuits; Resonance; Superconducting magnets; Wire;
Conference_Titel :
Particle Accelerator Conference, 1997. Proceedings of the 1997
Conference_Location :
Vancouver, BC
Print_ISBN :
0-7803-4376-X
DOI :
10.1109/PAC.1997.749547