• DocumentCode
    334067
  • Title

    Measurement of Tevatron extraction parameters and comparison of model to measurements

  • Author

    Martens, M.A. ; Marriner, J. ; Holt, J.

  • Author_Institution
    Fermi Nat. Accel. Lab., Batavia, IL, USA
  • Volume
    1
  • fYear
    1997
  • fDate
    12-16 May 1997
  • Firstpage
    72
  • Abstract
    An accurate model of the half integer resonance extraction process in the Tevatron requires a knowledge of the extraction parameters such as the strengths of the 39th harmonic quadrupole and 0th harmonic octupole. This paper describes a series of experiments that determine the extraction parameters. Results of target wire scans, which measure the profile of the extracted beam, are then compared to the Tevatron model
  • Keywords
    colliding beam accelerators; particle beam dynamics; particle beam extraction; proton accelerators; storage rings; synchrotrons; Tevatron extraction parameters; half integer resonance extraction process; harmonic octupole; harmonic quadrupole; target wire scans; Circuit topology; Integral equations; Laboratories; Lattices; Particle beams; Protons; RLC circuits; Resonance; Superconducting magnets; Wire;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1997. Proceedings of the 1997
  • Conference_Location
    Vancouver, BC
  • Print_ISBN
    0-7803-4376-X
  • Type

    conf

  • DOI
    10.1109/PAC.1997.749547
  • Filename
    749547