• DocumentCode
    3341011
  • Title

    Phased attenuation correction and respiratory motion compensation of pet image by using a ct images and multiple respiratory-phase mr images

  • Author

    Nam, Woo Ryun ; Lee, Duhgoon ; Ahn, Il Jun ; Jeong, Kye Young ; Kim, Ji Rye ; Ra, Jong Beam

  • Author_Institution
    Dept. of Electr. Eng., Korea Adv. Inst. of Sci. & Technol. (KAIST), Daejeon, South Korea
  • fYear
    2011
  • fDate
    23-29 Oct. 2011
  • Firstpage
    3792
  • Lastpage
    3795
  • Abstract
    Respiratory motion blurs positron emission tomography (PET) images in thorax and abdominal regions, and can cause attenuation-related errors in quantitative parameters. In addition, this motion can cause localization error and disappearance of tumor(s) near the diaphragm. Respiratory gated PET imaging, or 4D PET imaging, is an attractive solution. For 4D PET, a surrogate measurement of the patient´s breathing is made during the scan, and based on this measurement the list-mode PET data are sorted and reconstructed into multiple images. In several studies, it has been reported that 4D PET imaging recovers tumor volume more accurately than 3D PET imaging, and yields more accurate standard uptake values. In spite of its promise, 4D PET images suffer from statistical noise because only a fraction of the acquired data can be used in each image. Moreover, they also suffer from inconsistent attenuation correction due to mismatches between PET and CT images. In this paper, we propose a novel framework for phased attenuation correction and respiratory motion compensation for a 3D PET image by using a 3D CT image and multiple respiratory-phase 3D MR images. For phased attenuation correction, we generate and utilize 4D CT image obtained via non-rigid registrations among a 3D CT image and multiple respiratory-phase 3D MR images. A 3D PET image at a selected respiratory phase is then obtained by adding attenuation corrected multiple 3D PET images through non-rigid transformation. Experimental result for a clinical dataset shows that the proposed algorithm can provide much clearer organ boundary with improved quality than the conventional method in a 3D PET image.
  • Keywords
    biomedical MRI; computerised tomography; image reconstruction; image registration; medical image processing; motion compensation; pneumodynamics; positron emission tomography; statistical analysis; tumours; 3D CT imaging; 4D PET imaging; abdominal regions; attenuation corrected multiple 3D PET imaging; attenuation-related errors; breathing; diaphragm; localization error; multiple respiratory-phase 3D MR imaging; nonrigid registrations; nonrigid transformation; phased attenuation correction; positron emission tomography imaging; quantitative parameters; respiratory gated PET imaging; respiratory motion; respiratory motion compensation; statistical noise; thorax regions; tumors; Attenuation measurement; Biology; Biomedical imaging; Computed tomography; Logic gates; Phase measurement; Positron emission tomography;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE
  • Conference_Location
    Valencia
  • ISSN
    1082-3654
  • Print_ISBN
    978-1-4673-0118-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2011.6153718
  • Filename
    6153718