Functionality test of a readout circuit for a 1mm3 resolution clinical PET system
Author :
Zhai, Jinjian ; Vandenbroucke, Arne ; Reynolds, Paul D. ; Levin, Craig S.
Author_Institution :
Stanford Univ., Stanford, CA, USA
fYear :
2011
fDate :
23-29 Oct. 2011
Firstpage :
3945
Lastpage :
3949
Abstract :
We are developing a 1mm3 resolution Positron Emission Tomography (PET) camera dedicated to breast imaging, which collects high energy photons emitted from radioactively labeled agents injected in the patients to detect molecular signatures of breast cancer. The camera consists of 8 × 8 arrays of 1 × 1 × 1mm3 lutetium yttrium oxyorthosilicate (LYSO) crystals coupled to position sensitive avalanche photo-diodes (PSAPDs). The camera is built out of 2 panels each having 9 cartridges. A cartridge houses 8 layers of 16 dual LYSO-PSAPD modules and features 1024 readout channels. Amplification, shaping and triggering is done using the 36 channel RENA-3™ chip. 32 of these chips are needed per cartridge, or 576 for the entire camera. The RENA-3™ needs functionality and performance validation before assembly in the camera. A Chip Tester board was built to ensure RENA functionality and quality, featuring a 20,000-cycle chip holder and the ability to charge inject each channel individually. Lab View software was written to collect data on all RENA-3™ channels automatically. Charge was injected using an arbitrary waveform generator. Software was written to validate gain, linearity, cross talk, and timing noise characteristics. Gain is tested using a linear fit, typical values of gain are 13 and -16 for positive and negative injected charges respectively. Timing analysis was based on analyzing the phase shift between U and V timing channels. A phase shift of 90 ± 5° and timing noise of 2ns were considered acceptable.
Keywords :
avalanche photodiodes; biomedical equipment; cancer; mammography; medical computing; position sensitive particle detectors; positron emission tomography; readout electronics; LabView software; PET camera; RENA-3 chip; breast cancer; breast imaging; chip tester board; clinical PET system; functionality test; high energy photon; lutetium yttrium oxyorthosilicate crystals; position sensitive avalanche photodiodes; radioactively labeled agents; readout circuit; Chirp; Integrated circuits; Synchronization;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE
Conference_Location :
Valencia
ISSN :
1082-3654
Print_ISBN :
978-1-4673-0118-3
Type :
conf
DOI :
10.1109/NSSMIC.2011.6153750
Filename :
6153750
Link To Document :
بازگشت