• DocumentCode
    3342518
  • Title

    Evaluation of windowed image reconstruction for time-of-flight PET

  • Author

    Guo, Jinxia ; Kao, Chien-Min ; Xie, Qinguo

  • Author_Institution
    Dept. of Biomed. Eng., Huazhong Univ. of Sci. & Technol., Wuhan, China
  • fYear
    2011
  • fDate
    23-29 Oct. 2011
  • Firstpage
    4162
  • Lastpage
    4166
  • Abstract
    We have previously developed a windowed image reconstruction method that allows for region-of-interest (ROI) reconstruction from a subset of TOF PET data. As a result, the method may improve the reconstruction for a ROI by discarding data that are not particularly information-bearing to it but containing high statistical noise or unwanted events (scatter or random). In our previous paper, we have evaluated the performance of this method with numerical experiments and showed that it can improve the image signal-to-noise ratio (SNR) when considering only the true events. We also showed that it can recover the area near a high activity area better in comparison with the conventional filtered back-projection (FBP) algorithm for non-TOF PET and the convolved ramp and Gaussian with confidence weighting (CRG-CW) method for TOF-PET. In this work, we more extensively evaluate the performance of this windowed image reconstruction method by including also scatter and randoms in simulation. We evaluate the SNR of the reconstructed images in defined ROIs as well as the variations of the SNRs with the size of the window function. Our results indicate that the windowed image reconstruction method can generate images with higher SNRs relative to FBP images. In addition, when the ROI is small and nearby a high-activity structure, the windowed reconstruction method can generate better SNRs than do the CRG-CW method.
  • Keywords
    image reconstruction; numerical analysis; positron emission tomography; statistical analysis; Gaussian confidence weighting method; convolved ramp; filtered back-projection algorithm; numerical experiment; random event; region-of-interest reconstruction; scatter event; signal-to-noise ratio; statistical noise; time-of-flight PET; windowed image reconstruction;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE
  • Conference_Location
    Valencia
  • ISSN
    1082-3654
  • Print_ISBN
    978-1-4673-0118-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2011.6153796
  • Filename
    6153796