Title :
A method to calculate uncertainty of LISN conducted measurements
Author :
Heise, Edward R. ; Heise, Robert E W
Author_Institution :
Eastman Kodak Co., Rochester, NY, USA
Abstract :
A method to calculate uncertainty of a conducted test that uses line impedance stabilization networks (LISN) and tunable receivers is presented. The measurement data obtained when characterizing the input impedance of LISNs (artificial mains network) and the calibration of a receiver, normally available at an EMI test facility as part of the quality system, is used to calculate uncertainty. The uncertainty is determined using a tuned receiver and also when a receiver is “stepped” at 9 kHz increments across the spectrum. The resultant calculations are consistent with engineering experience and provides insight on what and where to incorporate improvements in existing operations
Keywords :
calibration; electric impedance measurement; electromagnetic interference; measurement uncertainty; receivers; EMI test facility; artificial mains network; conducted measurements; input impedance; line impedance stabilization networks; measurement data; quality system; receiver calibration; tunable receivers; uncertainty calculation; Bandwidth; Calibration; Coupling circuits; Frequency measurement; Government; Impedance measurement; Signal generators; System testing; Tunable circuits and devices; Uncertainty;
Conference_Titel :
Electromagnetic Compatibility, 1998. 1998 IEEE International Symposium on
Conference_Location :
Denver, CO
Print_ISBN :
0-7803-5015-4
DOI :
10.1109/ISEMC.1998.750096