• DocumentCode
    3345054
  • Title

    The pulse response of the APD meter

  • Author

    Zhou, Jialu ; Shen, Xueqi ; Fahua Lin

  • Author_Institution
    Dept. of Radio Eng., Southeast Univ., Nanjing, China
  • fYear
    1989
  • fDate
    8-10 Sep 1989
  • Firstpage
    501
  • Abstract
    The pulse response of an amplitude probability distribution (APD) meter is obtained by computer simulation. It is shown that the absolute pulse response of the APD meter complies with the CISPR recommendation for EMI measuring apparatus, but its relative pulse response does not comply with the CISPR recommendation when the repetition frequency of the periodic pulses is lower than 2 Hz. Computation results show that, in order to reduce the deviation between the pulse response of the APD meter and CISPR specification, the sampling frequency has to be high enough for the envelope mode of operation
  • Keywords
    computerised instrumentation; digital simulation; electromagnetic interference; probability; APD meter; CISPR recommendation; EMI; amplitude probability distribution meter; computer simulation; envelope mode; measuring apparatus; periodic pulses; pulse response; repetition frequency; sampling frequency; Electromagnetic interference; Probability; Simulation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 1989. Symposium Record. 1989 International Symposium on
  • Conference_Location
    Nagoya
  • Type

    conf

  • DOI
    10.1109/ISEMC.1989.240864
  • Filename
    240864