Title :
Automation of testing line-coupled emissions
Author :
Bai, Li Zhou ; Chong, Weng Hoe
Author_Institution :
EMC Test Center, Singapore
Abstract :
In this paper, FCC and CISPR EMC requirements for line-conducted emissions from 450 kHz/150 kHz to 30 MHz are presented. However, radiated emissions from 30 MHz to 1 GHz (CISPR) and above (FCC) must be tested in an open area test site (OATS) which is expensive for small and medium companies. This paper introduces a current measurement method to predict the radiated emissions from external cables of EUT. This will help the manufacturer preliminary evaluate the radiated emission levels of digital devices from 30 MHz to 1 GHz. To facilitate the testing, an automated system is developed to fulfil the compliance conducted emission testing on power cable and preliminary radiated emission testing on signal/control cables using cable current measurement method
Keywords :
automatic testing; electric current measurement; electromagnetic compatibility; electromagnetic interference; power cable testing; 150 kHz to 1 GHz; CISPR EMC requirement; EUT; FCC EMC requirements; automated testing; compliance conducted emission testing; control cables; current measurement method; digital devices; external cables; line-conducted emissions; line-coupled emissions testing; power cable; radiated emissions; signal cables; Automatic control; Automatic testing; Automation; Current measurement; Electromagnetic compatibility; FCC; Manufacturing; Open area test sites; Power cables; System testing;
Conference_Titel :
Electromagnetic Compatibility, 1998. 1998 IEEE International Symposium on
Conference_Location :
Denver, CO
Print_ISBN :
0-7803-5015-4
DOI :
10.1109/ISEMC.1998.750124