• DocumentCode
    334601
  • Title

    First test of orbit response matrix in proton storage ring

  • Author

    Chu, C.M. ; Ball, M. ; East, G. ; Hamilton, B. ; Jeon, D. ; Kang, X. ; Kiang, L.L. ; Lee, S.Y. ; Ng, K.Y. ; Pei, A. ; Riabko, A. ; Sloan, T.

  • Author_Institution
    Cyclotron Facility, Indiana Univ., Bloomington, IN, USA
  • Volume
    2
  • fYear
    1997
  • fDate
    12-16 May 1997
  • Firstpage
    1481
  • Abstract
    The orbit response matrix method is applied to experimentally determine the Cooler Ring optics at the Indiana University Cyclotron Facility (IUCF). We have carried out two experiments in Oct. And Nov. 1996 to measure the orbit response of the IUCF Cooler Ring. An analysis software was adopted from the NSLS, BNL. In our analysis, strength error in quadrupoles and steering dipoles, and amplifier gain in BPMs are included as fitting parameters. However, effects of the linear and non-linear coupling are excluded in our preliminary analysis. Since the resolution of our BPM system is of the order of 10 μm, we will address the effect of BPM resolution on the applicability of the orbit response matrix method in proton storage rings
  • Keywords
    accelerator magnets; cyclotrons; electromagnets; ion optics; particle beam diagnostics; proton accelerators; storage rings; Cooler Ring optics; IUCF; Indiana University Cyclotron Facility; beam position monitors; orbit response matrix; proton storage ring; quadrupoles; steering dipoles; Cyclotrons; Error analysis; Extraterrestrial measurements; Nonlinear optics; Notice of Violation; Optical amplifiers; Protons; Stimulated emission; Storage rings; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1997. Proceedings of the 1997
  • Conference_Location
    Vancouver, BC
  • Print_ISBN
    0-7803-4376-X
  • Type

    conf

  • DOI
    10.1109/PAC.1997.750733
  • Filename
    750733