DocumentCode
3346650
Title
Proper specification and installation of induction motors
Author
Finley, W.R. ; Burke, R.R.
Author_Institution
Motors & Drives Div., Siemens Energy & Autom. Inc., Norwood, OH, USA
fYear
1995
fDate
11-13 Sep 1995
Firstpage
285
Lastpage
297
Abstract
When selecting a motor, decisions must be made as to characteristics of performance, degree of protection, and maintainability. A minimum suitable motor for the application is chosen, then evaluations of the expense related to increased protection and optional features and performance. After receipt, the motor must be installed and maintained properly to give the long and trouble-free life desired. The authors discuss the factors involved in motor selection, environmental factors, installation and control settings, and commissioning tests
Keywords
commissioning; induction motor protection; installation; machine control; machine testing; maintenance engineering; commissioning tests; environmental factors; induction motors; maintainability; motor control settings; motor installation; motor protection; optional features; Automation; Costs; Filters; Induction motors; Insulation; Noise level; Protection; Stators; Vibration control; Working environment noise;
fLanguage
English
Publisher
ieee
Conference_Titel
Petroleum and Chemical Industry Conference, 1995. Record of Conference Papers., Industry Applications Society 42nd Annual
Conference_Location
Denver, CO
ISSN
0090-3507
Print_ISBN
0-7803-2909-0
Type
conf
DOI
10.1109/PCICON.1995.523964
Filename
523964
Link To Document