DocumentCode :
334897
Title :
Electron bunch length diagnostic with coherent Smith-Purcell radiation
Author :
Nguyen, D.C.
Author_Institution :
Los Alamos Nat. Lab., NM, USA
Volume :
2
fYear :
1997
fDate :
12-16 May 1997
Firstpage :
1990
Abstract :
We have designed a new technique for measuring subpicosecond electron bunch lengths using coherent Smith-Purcell radiation. This new diagnostic technique involves passing the electron beam in close proximity of a grating with period comparable to the electron bunch length. The emitted Smith-Purcell radiation will have a coherent component whose angular position and distribution are directly related to the electron bunch length and longitudinal profile, respectively. This new diagnostic technique is inherently simple, inexpensive and non-intercepting. We show that the new technique is also scaleable to femtosecond regime
Keywords :
electron beams; particle beam bunching; particle beam diagnostics; 1 fs; coherent Smith-Purcell radiation; electron beam; electron bunch lengths; femtosecond; longitudinal profile; subpicosecond; Detectors; Diffraction gratings; Electron beams; Electron emission; Laboratories; Length measurement; Light sources; Mirrors; Plasma accelerators; Synchrotron radiation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 1997. Proceedings of the 1997
Conference_Location :
Vancouver, BC
Print_ISBN :
0-7803-4376-X
Type :
conf
DOI :
10.1109/PAC.1997.751083
Filename :
751083
Link To Document :
بازگشت