DocumentCode :
334930
Title :
Comparison of beam-position-transfer functions using circular beam-position monitors
Author :
Gilpatrick, J.D.
Author_Institution :
Los Alamos Nat. Lab., NM, USA
Volume :
2
fYear :
1997
fDate :
12-16 May 1997
Firstpage :
2090
Abstract :
A cylindrical beam-position monitor (BPM) used in many accelerator facilities has four electrodes on which beam-image currents induce bunched-beam signals. These probe-electrode signals are geometrically configured to provide beam-position information about two orthogonal axes. An electronic processor performs a mathematical transfer function (TF) on these BPM-electrode signals to produce output signals whose time-varying amplitude is proportional to the beam´s vertical and horizontal position. This paper compares various beam-position TFs using both pencil beams and further discuss how diffuse beams interact with some of these TFs
Keywords :
particle beam diagnostics; position measurement; beam-image currents; beam-position information; beam-position-transfer functions; bunched-beam signals; circular beam-position monitors; mathematical transfer function; pencil beams; probe-electrode signals; time-varying amplitude; Control systems; Electrodes; Nonlinear equations; Particle beams; Polynomials; Position measurement; Probes; Signal analysis; Signal processing; Transfer functions;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 1997. Proceedings of the 1997
Conference_Location :
Vancouver, BC
Print_ISBN :
0-7803-4376-X
Type :
conf
DOI :
10.1109/PAC.1997.751117
Filename :
751117
Link To Document :
بازگشت