• DocumentCode
    3349546
  • Title

    New Method for Detecting Failures of Power Converter Module in Control Rod Control System

  • Author

    Cheon, Jong-Min ; Kim, Choon-Kyoug ; Lee, Jong-Moo ; Kwon, Soonman

  • Author_Institution
    Korea Electrotechnol. Res. Inst.
  • Volume
    2
  • fYear
    2006
  • fDate
    9-13 July 2006
  • Firstpage
    1566
  • Lastpage
    1570
  • Abstract
    In this paper, we introduce a new method for detecting failures of a power converter module in control rod control system of a nuclear power plant. The failure called the phase failure and occurring in a power converter module can exert harmful influence upon the operation of the associated control rod drive mechanism for driving neutron-absorbing control rods controlling the thermal output of the reactor. Because of this adverse condition, it is necessary that the phase failure should be detected quickly and correctly. We devised a new method for detecting the phase failure for the digital power controller and solved the drawbacks of the existing failure detector
  • Keywords
    fission reactors; neutron absorption; nuclear power stations; power control; power convertors; power generation control; power generation faults; control rod control system; control rod drive mechanism; digital power controller; failure detection; neutron-absorbing control rods; nuclear power plant; phase failure; power converter module; Coils; Control systems; Cyclic redundancy check; Detectors; Digital control; Grippers; Inductors; Phase detection; Thyristors; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial Electronics, 2006 IEEE International Symposium on
  • Conference_Location
    Montreal, Que.
  • Print_ISBN
    1-4244-0496-7
  • Electronic_ISBN
    1-4244-0497-5
  • Type

    conf

  • DOI
    10.1109/ISIE.2006.295705
  • Filename
    4078320