Title :
Analysis for Electric Loads of Residential Buildings During Summer in Wuhan
Author :
Ye, Xiao Jiang ; Zhou, Zhao Xia ; Er, Qing ; Wu, Feng ; Chen, Huan Xin
Author_Institution :
Sch. of Sci., Wuhan Inst. of Technol., Wuhan
Abstract :
Air conditioner electric load was the most significant factor for residential electrical peak load. Outdoor environmental parameters such as outdoor air temperature and humidity might have effect on air conditioner electric load. A field testing was carried out in Wuhan to study the relationship among residential electric load, outdoor air temperature and humidity. The result showed that the changing of air conditioner electric load was closed to outdoor air temperature and there were linear relationship in some temperature zone. However, it had a little effect on daily basic electric load. There was no evident indicate that humidity had directly effect on air conditioner electric load and basic electric load with the testing data.
Keywords :
air conditioning; humidity; load forecasting; load management; Air conditioner; Wuhan; electric load analysis; outdoor air temperature; outdoor humidity; residential buildings; residential electrical peak load; Cooling; Economic forecasting; Erbium; Humidity; Load forecasting; Power generation; Power system reliability; Rivers; Temperature; Testing;
Conference_Titel :
Power and Energy Engineering Conference, 2009. APPEEC 2009. Asia-Pacific
Conference_Location :
Wuhan
Print_ISBN :
978-1-4244-2486-3
Electronic_ISBN :
978-1-4244-2487-0
DOI :
10.1109/APPEEC.2009.4918151