DocumentCode :
3350500
Title :
Analysis of the Circular Volt-Detecting Method of Individual Cells Involved in the Supercapacitor Bank
Author :
Zhang Yicheng ; Liang Haiquan ; Xun Haitao ; Wu LuLu
Author_Institution :
Coll. of Electron. & Inf. Eng., Tongji Univ., Shanghai
fYear :
2009
fDate :
27-31 March 2009
Firstpage :
1
Lastpage :
4
Abstract :
The voltage of single supercapacitor is no more than 1.6 V. So a lot of cells are combined to a bank in order to reach higher voltages which make it possible for a high efficient transformation from the supercapacitor bank. Sometimes hundreds of cells are connected whereas the voltages of the cells differ with others. So proper measure should be taken to detect the voltages of the individual cells. This paper represents a new method of detecting the voltages of cells quickly. A microprocessor is implied to control the multi channels. This method is much faster and more accurate than those done by relays or voltage distribution by resistors. It is implied in the capacitor bank which contents 20 cells and gains a good result. It costs 1 ms to detect each capacitor and the precision reaches 2 mV. As the detecting board is powered directly by supercapacitors and CAN bus is applied to connect the boards, it is more suitable for detecting voltages of super capacitors in vehicles.
Keywords :
controller area networks; supercapacitors; CAN bus; circular volt-detecting method; individual cells; microprocessor; supercapacitor bank; Capacitors; Costs; Energy storage; Relays; Resistors; Size measurement; Supercapacitors; Vehicle detection; Velocity measurement; Voltage measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power and Energy Engineering Conference, 2009. APPEEC 2009. Asia-Pacific
Conference_Location :
Wuhan
Print_ISBN :
978-1-4244-2486-3
Electronic_ISBN :
978-1-4244-2487-0
Type :
conf
DOI :
10.1109/APPEEC.2009.4918163
Filename :
4918163
Link To Document :