DocumentCode :
3356714
Title :
Performance comparison of small GYGAG (Ce) and CsI(Tl) scintillators with PIN detectors
Author :
Kindem, Joel ; Conwell, Richard ; Cherepy, N.J. ; Payne, S.A.
Author_Institution :
Digirad Corp., Poway, CA, USA
fYear :
2011
fDate :
23-29 Oct. 2011
Firstpage :
1621
Lastpage :
1623
Abstract :
Background: Thallium doped CsI(Tl) scintillators read out with PIN photodiodes have been successfully used for high performance pixilated solid-state gamma cameras for cardiac SPECT and general nuclear systems. These cameras allow for both emission and transmission scans because of their good energy resolution and count-rate performance. We have reported previously on the performance of detector modules employing small CsI(Tl) scintillators (2.8×2.8×6mm) where the dominant limiting factor for both energy resolution and count-rate performance is CsI(Tl) itself. Methods: We compared identical shaped CsI(Tl) and newly introduced Ce-doped (Gd,Y)3(Al, Ga)5O12 (GYGAG) transparent ceramics (with fast decay time), read out with our PIN photodiode based detector modules, characterizing the light yield, energy resolution and count-rate performance obtainable with GYGAG at 140keV. Results: We measured luminosities of 42,000 and 64,000 Ph./MeV for GYGAG and CsI(Tl) respectively. GYGAG had a decay time that allowed use of a 6μs shaping time instead of the 12μs required for optimal energy resolution with CsI(Tl), enabling >;2x improvement in count-rate performance. Though GYGAG was more proportional than CsI(Tl), the energy resolution was not improved over CsI(Tl) at 140keV due to its lower luminosity. However, we measured energy resolution of 4.0% at 662keV for GYGAG on our 3mm photodiode detector modules, better than the 5.3% estimated for CsI(Tl). After exposure to ambient light, GYGAG´s residual fluorescence was ~800 times that from CsI(Tl) and had 3 decay components. The longest component contributed at 6% of the total, and had a decay time troublesome for PMT measurements, though it did not significantly affect the energy resolution measured with photodiodes.
Keywords :
caesium compounds; gadolinium compounds; photodiodes; solid scintillation detectors; yttrium compounds; (GdY)3(AlGa)5O12:Ce; CsI(Tl); GYGAG(Ce) scintillator; PIN detectors; PIN photodiodes; PMT measurements; cardiac SPECT system; count-rate performance; dominant limiting factor; general nuclear system; optimal energy resolution; photodiode detector modules; solid-state gamma cameras; thallium doped CsI(Tl) scintillator; Energy measurement; Garnets; Logic gates;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE
Conference_Location :
Valencia
ISSN :
1082-3654
Print_ISBN :
978-1-4673-0118-3
Type :
conf
DOI :
10.1109/NSSMIC.2011.6154646
Filename :
6154646