DocumentCode
3356732
Title
Optimizing Scheme of Power Delivery for Small Thermal Power Generating Units Under Emergency
Author
Li, Yu ; Guo, Lin
Author_Institution
Energy & Environ. Res. Center, North China Electr. Power Univ., Beijing
fYear
2009
fDate
27-31 March 2009
Firstpage
1
Lastpage
3
Abstract
An optimization model was established based on the small thermal power generating units (STPGUs) as one of the effective emergency measures of power delivery in the natural disaster areas (such as the snow disaster on January 28, 2008, in China), which was subject to certain reliability and constraints including time and power capacity. The model was performed in a case study to minimum the total cost: the operating costs of small thermal power generating units (MC) and power customer interruption cost function (OC) using MATLAB, and the results showed that the optimization scheme of emergency power for STPGUs could meet the challenge of emergent power delivery caused by the natural disaster, although the STPGUs has been closing-down in China due to its "high-energy-consumption, high pollution".
Keywords
costing; optimisation; power consumption; power generation reliability; thermal power stations; MATLAB; cost function; emergency power delivery scheme; energy-consumption; natural disaster; optimization scheme; power generation reliability; thermal power generating unit; Area measurement; Constraint optimization; Cost function; Mathematical model; Pollution measurement; Power generation; Power measurement; Snow; Thermal pollution; Time measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Power and Energy Engineering Conference, 2009. APPEEC 2009. Asia-Pacific
Conference_Location
Wuhan
Print_ISBN
978-1-4244-2486-3
Electronic_ISBN
978-1-4244-2487-0
Type
conf
DOI
10.1109/APPEEC.2009.4918579
Filename
4918579
Link To Document