• DocumentCode
    3356985
  • Title

    The design of the condenser in the evaporative cooling hydro generators

  • Author

    Lin, Ruan ; Guobiao, Gu ; Jianhua, He ; Xindong, Tian

  • Author_Institution
    Inst. of Electr. Eng., Chinese Acad. of Sci., Beijing
  • fYear
    2007
  • fDate
    10-12 Sept. 2007
  • Firstpage
    309
  • Lastpage
    312
  • Abstract
    The condenser is the key component in the evaporative cooling hydro generator. The design of the condenser will directly affect the performance of the whole evaporative cooling system as well as the temperature distribution of the stator bar. So, this paper introduced the method of the arrangement of condensers and the design of the capacity of each single condenser. Especially, under unsymmetrical operating state of the condenser, the influence of which on the cooling effect was analyzed. This will provide the reference for the design of the condenser.
  • Keywords
    cooling; evaporation; hydroelectric generators; power capacitors; stators; temperature distribution; condenser design; evaporative cooling system; hydro generator; stator bar; temperature distribution; Coolants; Cooling; Helium; Machinery; Maintenance; Resistance heating; Roads; Stator bars; Temperature distribution; Water heating; capacity; condenser; evaporative cooling hydro generator; temperature distribution;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines and Power Electronics, 2007. ACEMP '07. International Aegean Conference on
  • Conference_Location
    Bodrum
  • Print_ISBN
    978-1-4244-0890-0
  • Electronic_ISBN
    978-1-4244-0891-7
  • Type

    conf

  • DOI
    10.1109/ACEMP.2007.4510525
  • Filename
    4510525