The design of the condenser in the evaporative cooling hydro generators
Author :
Lin, Ruan ; Guobiao, Gu ; Jianhua, He ; Xindong, Tian
Author_Institution :
Inst. of Electr. Eng., Chinese Acad. of Sci., Beijing
fYear :
2007
fDate :
10-12 Sept. 2007
Firstpage :
309
Lastpage :
312
Abstract :
The condenser is the key component in the evaporative cooling hydro generator. The design of the condenser will directly affect the performance of the whole evaporative cooling system as well as the temperature distribution of the stator bar. So, this paper introduced the method of the arrangement of condensers and the design of the capacity of each single condenser. Especially, under unsymmetrical operating state of the condenser, the influence of which on the cooling effect was analyzed. This will provide the reference for the design of the condenser.
Keywords :
cooling; evaporation; hydroelectric generators; power capacitors; stators; temperature distribution; condenser design; evaporative cooling system; hydro generator; stator bar; temperature distribution; Coolants; Cooling; Helium; Machinery; Maintenance; Resistance heating; Roads; Stator bars; Temperature distribution; Water heating; capacity; condenser; evaporative cooling hydro generator; temperature distribution;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines and Power Electronics, 2007. ACEMP '07. International Aegean Conference on
Conference_Location :
Bodrum
Print_ISBN :
978-1-4244-0890-0
Electronic_ISBN :
978-1-4244-0891-7
Type :
conf
DOI :
10.1109/ACEMP.2007.4510525
Filename :
4510525
Link To Document :
بازگشت