Title :
Periodic Jitter Amplitude Calibration with Walking Strobe
Author :
Liu, Lucy ; Lew, Eddie
Author_Institution :
Teradyne, Inc., Agoura Hills, CA
Abstract :
Jitter insertion is a feature an automatic test equipment (ATE) provides for high speed SerDes device jitter tolerance testing. The amplitude of inserted periodic jitter (PJ) and its frequency are programmable. This article focuses on a technique developed to measure and calibrate the PJ amplitude of the ATE jitter insertion circuit. It uses a measurement tool called the walking strobe to systematically capture the jittered waveform and reconstruct it such that the jitter amplitude measurement consists of a series of edge time measurements. The method is accurate, fast, and low cost. This paper will also present experimental results
Keywords :
automatic test equipment; calibration; timing jitter; amplitude calibration; automatic test equipment; edge time measurements; high speed SerDes device; inserted periodic jitter; jitter tolerance testing; walking strobe; Calibration; Circuit testing; Clocks; Costs; Frequency; Jitter; Legged locomotion; Oscilloscopes; Time measurement; Voltage control;
Conference_Titel :
Test Conference, 2006. ITC '06. IEEE International
Conference_Location :
Santa Clara, CA
Print_ISBN :
1-4244-0292-1
Electronic_ISBN :
1089-3539
DOI :
10.1109/TEST.2006.297714