Test and Correlative Formula of Boiler Superheater Inner-Flue and Outer-Flue Tube Wall Temperature
Author :
Yu Yanzhi ; Xu Haichuan ; Biguang, T.
Author_Institution :
Sch. of Power & Mech. Eng., Wuhan Univ., Wuhan
fYear :
2009
fDate :
27-31 March 2009
Firstpage :
1
Lastpage :
4
Abstract :
In order to monitor tube wall temperature of boiler superheater, a new method was put forward to observe inner-flue tube wall temperature by long-term measuring outer-flue tube wall temperature. The method was based on the relation between inner-flue tube wall temperature and outer-flue tube wall temperature that was build up through testing data. The testing points were settled on the inner-flue and the outer-flue of same tube. According to the experimental data, the inner-outer flue tube wall temperature relation modeling was build up and checked.
Keywords :
boilers; heat transfer; steam power stations; temperature measurement; boiler superheater; correlative formula; inner-flue tube wall temperature; outer-flue tube wall temperature; steam generating system; Boilers; Delay; Flue gases; Mechanical engineering; System testing; Temperature distribution; Temperature measurement; Temperature sensors; Thermal stresses; Thermoelectricity;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power and Energy Engineering Conference, 2009. APPEEC 2009. Asia-Pacific
Conference_Location :
Wuhan
Print_ISBN :
978-1-4244-2486-3
Electronic_ISBN :
978-1-4244-2487-0
Type :
conf
DOI :
10.1109/APPEEC.2009.4918860