Title :
D-dot and B-dot monitors for Z-vacuum section power-flow measurements
Author :
Stygar, W.A. ; Spielman, R.B. ; Ives, H.C. ; Moore, W.B.S. ; Seamen, J.F. ; Sharpe, A.W. ; Wagoner, T.C. ; Gilliland, T.L. ; Broyles, R.S. ; Mills, J.A. ; Dinwoodie, T.A. ; Slopek, J.S. ; Struve, K.W. ; Reynolds, P.G.
Author_Institution :
Sandia Nat. Labs., Albuquerque, NM, USA
fDate :
June 29 1997-July 2 1997
Abstract :
New differential D-dot and B-dot monitors were developed for the Z vacuum section of an accelerator pulsed power supply. The D-dots measure voltage at the insulator stack. The B-dots measure current at the stack and in the outer magnetically-insulated transmission lines. Each monitor has two outputs that allow common-mode noise to be cancelled to the first order. The differential D-dot has one signal and one noise channel; the differential B-dot has two signal channels with opposite polarities. Each of the two B-dot sensors in the differential B-dot monitor has four 3 mm diameter loops and is encased in copper to reduce flux penetration. For both types of probes, two 2.2 mm diameter coaxial cables connect the outputs to a Prodyn balun for common-mode-noise rejection. The cables provide reasonable bandwidth and generate acceptable levels of Compton drive in the bremsstrahlung field of the Z accelerator. A new cavity B-dot is being developed to measure the total Z current 4.3 cm from the axis of the z-pinch load. All of the sensors are calibrated with 2-4% accuracy. The monitor signals are reduced with Barth or Weinschel attenuators, recorded on Tektronix 0.5 ns/sample digitizing oscilloscopes, and software cable compensated and integrated.
Keywords :
particle accelerators; 2.2 mm; 3 mm; 4.3 cm; Compton drive; Z-vacuum section; accelerator pulsed power supply; bandwidth; bremsstrahlung field; common-mode noise cancellation; current measurements; differential B-dot monitor; differential D-dot monitor; magnetically-insulated transmission lines; power-flow measurements; sensor calibration; voltage measurements; z-pinch load; Cables; Current measurement; Insulation; Magnetic flux; Magnetic noise; Noise cancellation; Power transmission lines; Pulsed power supplies; Transmission line measurements; Voltage measurement;
Conference_Titel :
Pulsed Power Conference, 1997. Digest of Technical Papers. 1997 11th IEEE International
Conference_Location :
Baltimore, MA, USA
Print_ISBN :
0-7803-4213-5
DOI :
10.1109/PPC.1997.674573