  • Abstract
    This study describes a new method for evaluating polyethylene wear in total knee prosthesis. Since the amount of wear is dependent on a number of variables such as weight and activity of the patient, the amount should be estimated based on in-vivo measurement. A computer vision technique called 3D/2D matching is employed to perform in-vivo assessment using single-plane radiograph. By the 3D/2D matching algorithm the three-dimensional position and orientation (pose) of knee implants is estimated to measure the femorotibial distance which is defined as the shortest perpendicular distance from the tibial tray to the femoral component. The accuracy of the proposed 3D/2D matching method is demonstrated on some in-vitro investigations. Pose estimation errors are examined and the maximum error in in-plane/out-of-plane translations and rotations 0.28/4.17 mm and 0.33/0.26 degrees, respectively. That in femorotibial distance measurements is 0.14 mm
  • Keywords
    biomechanics; biomedical materials; biomedical measurement; computer vision; diagnostic radiography; image matching; medical image processing; polymers; position measurement; prosthetics; wear; wear testing; 3D orientation; 3D pose estimation method; 3D/2D matching; computer vision technique; femoral component; femorotibial distance; in-plane/out-of-plane rotations; in-plane/out-of-plane translations; in-vitro investigations; in-vivo measurement; knee implants; polyethylene wear assessment; pose estimation errors; shortest perpendicular distance; single-plane radiograph; tibial tray; total knee prosthesis; total knee replacement; Computer vision; Diagnostic radiography; Distance measurement; Estimation error; Implants; In vitro; Knee; Polyethylene; Position measurement; Prosthetics;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 1997. Proceedings of the 19th Annual International Conference of the IEEE
  • Conference_Location
    Chicago, IL
  • ISSN
    1094-687X
  • Print_ISBN
    0-7803-4262-3
  • Type

    conf

  • DOI
    10.1109/IEMBS.1997.757093
  • Filename
    757093