• DocumentCode
    3364926
  • Title

    MEMS phased array detection in contact with solids

  • Author

    Greve, D.W. ; Jain, A. ; Oppenheim, I.J.

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Carnegie Mellon Univ., Pittsburgh, PA, USA
  • Volume
    2
  • fYear
    2002
  • fDate
    8-11 Oct. 2002
  • Firstpage
    1035
  • Abstract
    We report on the development of transducers for ultrasonic flaw detection which can be permanently mounted at critical locations on structures. We will show that MEMS capacitive diaphragm transducers can be bonded to metal or plexiglas test specimens without damage and that ultrasonic energy can be efficiently coupled into the transducer. It will be demonstrated that transducer arrays can be operated as a phased array in order to determine the direction and distance of an ultrasonic source. In addition, the detection of flaws or voids in a test specimen will also be demonstrated.
  • Keywords
    capacitive sensors; diaphragms; flaw detection; microsensors; plastics; ultrasonic materials testing; ultrasonic transducer arrays; voids (solid); MEMS capacitive diaphragm transducers; MEMS phased array detection; critical locations; flaws; metal test specimens; plexiglas test specimens; ultrasonic flaw detection; voids; Acoustic transducers; Bonding; Detectors; Frequency; Micromechanical devices; Phase detection; Phased arrays; Solids; Ultrasonic transducer arrays; Ultrasonic transducers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium, 2002. Proceedings. 2002 IEEE
  • ISSN
    1051-0117
  • Print_ISBN
    0-7803-7582-3
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2002.1192472
  • Filename
    1192472