Title :
Proton radiation test of DC/DC converter with high voltage output
Author :
Scherrer, S. ; Hajdas, Wojtek ; Grossner, U. ; Schlumpf, N.
Author_Institution :
Paul Scherrer Inst., Villigen, Switzerland
Abstract :
Radiation hardness of the COTS high voltage DC-DC converter was tested up to 90 krad(Si) using proton beams. Total dose effects with subsequent annealing were determined. Dependence on operating conditions and dose rate was observed. Mainly responsible parts were identified and functional failure of the device was attributed to the input current increase driven by power MOSFET.
Keywords :
DC-DC power convertors; power MOSFET; proton beams; DC-DC converter; commercials off the shelf; dose rate; functional failure; power MOSFET; proton beam; proton radiation test; radiation hardness; total dose effects; Annealing; Current measurement; DC-DC power converters; Laser beams; Radiation effects; Switches; Voltage measurement; Annealing; DC-DC power conversion; Proton beams; Radiation effects;
Conference_Titel :
Radiation and Its Effects on Components and Systems (RADECS), 2008 European Conference on
Conference_Location :
Jyvaskyla
Print_ISBN :
978-1-4577-0481-9
DOI :
10.1109/RADECS.2008.5782686