DocumentCode
3368700
Title
PVDE-ultrasound transducer arrays with a reduced number of elements using matched receiver arrays
Author
Blessing, H.
Author_Institution
Inst. fur Mess- und Regelungstech., Karlsruhe Univ., Germany
fYear
1992
fDate
12-14 May 1992
Firstpage
59
Lastpage
64
Abstract
A combination of transmitting and receiving ultrasound arrays is presented and analyzed. The arrays are composed of polyvinylidene-fluoride (PVDF)-membrane transducers, a new type of transducer well suited for applications in low-impedance media like air. PVDF transducers offer a broadband impulse response. Computer simulations, as well as measured characteristics, are presented and show the effectiveness of the transmitter-receiver combination which is used for sector B-scans
Keywords
acoustic arrays; acoustic imaging; digital simulation; polymer films; ultrasonic transducers; B-scans; PVDE-ultrasound transducer arrays; US imaging; air; broadband impulse response; computer simulation; matched receiver arrays; membrane transducers; polymer films; polyvinylidene-fluoride; transmitter-receiver; Acoustic transducers; Apertures; Convolution; Costs; Gratings; Phased arrays; Planar arrays; Ultrasonic imaging; Ultrasonic transducer arrays; Ultrasonic transducers;
fLanguage
English
Publisher
ieee
Conference_Titel
Instrumentation and Measurement Technology Conference, 1992. IMTC '92., 9th IEEE
Conference_Location
Metropolitan, NY
Print_ISBN
0-7803-0640-6
Type
conf
DOI
10.1109/IMTC.1992.245176
Filename
245176
Link To Document