DocumentCode
3369338
Title
Initial Results from Experiments with a Reflex Triode Powered by a Marx Generator
Author
Hurtig, Tomas ; Nylander, Cecilia ; Appelgren, Patrik ; Elfsberg, Mattias ; Larsson, Anders ; Nyholm, Sten E.
Author_Institution
Weapons & Protection Div., Swedish Defence Res. Agency, Tumba
fYear
2005
fDate
13-17 June 2005
Firstpage
198
Lastpage
201
Abstract
The reflex triode is a device used for the generation of high-power microwave (HPM) radiation. This study presents an experimental investigation of a reflex triode, powered by a 400 kV Marx generator, and also gives a comparison between theoretically and experimentally obtained scaling laws. The experimentally determined dominating frequency from the reflex triode with different anode-cathode gaps agree qualitatively well with the theoretical expression, but in general the experimental frequency is lower.
Keywords
anodes; cathodes; microwaves; pulsed power supplies; triodes; Marx generator; anode-cathode gaps; high-power microwave radiation; reflex triode; scaling laws; Anodes; Cathodes; Frequency; High power microwave generation; Microwave devices; Microwave generation; Power generation; Probes; Steel; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Pulsed Power Conference, 2005 IEEE
Conference_Location
Monterey, CA
Print_ISBN
0-7803-9189-6
Electronic_ISBN
0-7803-9190-x
Type
conf
DOI
10.1109/PPC.2005.300559
Filename
4084186
Link To Document