DocumentCode :
3373703
Title :
Analysis of data pad open failure
Author :
Yang, Heejung ; Lee, Jaemin ; Han, Gyuwon ; Han, Seunghoon ; Oh, Duseok ; Kim, Dongsun ; Kim, Hyungtae ; Ho, Wonjoon ; Jeong, Juyoung
Author_Institution :
LG Display Panel Center, Paju, South Korea
fYear :
2012
fDate :
2-6 July 2012
Firstpage :
1
Lastpage :
3
Abstract :
We have investigated pad open failure of data line. To verify the mechanism of DPO failure, we designed the new method included in CCD camera and driving circuit and successfully achieved the failure images. The DPO procedure was divided into three steps. First, side wall of Cu film was exposed to Cl plasma and then CuClx compounds formed on surface of Cu film. Subsequently, when it was rinsed by DI water, CuClx was decomposed into Cu and HCl. As a result, etch taper was changed to be abnormal because of re-etching of Cu surface due to HCl. Second, passivation layer was deposited on the data line with poor step coverage. Finally, the panel with poor step coverage was introduced to cleaning bath before module processing and residual water still remained on the data pad area by final operating inspection. Under these conditions, when the operating voltage was applied to the panel, migration of Cu was easily occurred. As a result, we successfully verified the mechanism of DPO in real time.
Keywords :
CCD image sensors; driver circuits; failure analysis; passivation; CCD camera; DPO failure; data line; data pad open failure analysis; driving circuit; failure images; passivation layer; Glass; Optical films; Optical imaging; Passivation; Scanning electron microscopy; Thin film transistors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Physical and Failure Analysis of Integrated Circuits (IPFA), 2012 19th IEEE International Symposium on the
Conference_Location :
Singapore
ISSN :
1946-1542
Print_ISBN :
978-1-4673-0980-6
Type :
conf
DOI :
10.1109/IPFA.2012.6306312
Filename :
6306312
Link To Document :
بازگشت