Title :
A Compact High Current Generator for X-Ray Radiography
Author :
Kovalchuk, B.M. ; Kharlov, A.V. ; Zorin, V.B.
Author_Institution :
Inst. of High Current Electron., Tomsk
Abstract :
X-generator was designed for small scale experiments with imploding liners, especially X-pinches. The generator consists of the capacitor bank, multi-channel multi-gap spark switch, flat current buses, load chamber and built-in high voltage triggering generator. The capacitor bank consists of 12 General Atomics 35404 type capacitors (20 nF, 25 nH, 0.2 Ohm, 100 kV). It stores ~0.8 kJ at 80 kV charging voltage. . Each three capacitors are commuted to a load by multi-gap spark switch, which is able to commute by 8 parallel channels. Switches operate in ambient air at atmospheric pressure. The X-generator was tested with 5 and 10.5 nH inductive loads. At 76 kV charging voltage the generator provides ~260 kA with 120 ns risetime with 5 nH inductive load and -220 kA with 145 ns risetime with 10.5 nH. Delay of output pulse relatively to high voltage triggering pulse was 65 ns with 5 ns jitter ( at 76 kV charging voltage). Dimensions of the generator are 1240times1240times225 mm and weight is ~250 kg, so it could be easily employed for variety of applications.
Keywords :
capacitor storage; pulsed power switches; spark gaps; X-generators; X-ray radiography; atmospheric pressure; built-in high voltage triggering generator; capacitor bank; compact high current generator; high voltage triggering pulse; multichannel multigap spark switch; multigap spark switch; small scale experiments; voltage 76 kV; voltage 80 kV; Capacitors; Electrodes; Flanges; Insulation; Power cables; Radiography; Sparks; Switches; Testing; Voltage;
Conference_Titel :
Pulsed Power Conference, 2005 IEEE
Conference_Location :
Monterey, CA
Print_ISBN :
0-7803-9189-6
Electronic_ISBN :
0-7803-9190-x
DOI :
10.1109/PPC.2005.300614